FEATURE-PACKED BOILERS WITH INNOVATIVE
IDEAS
Reasonable Price
By comparing the performance, safety, and operational ease,
between Thermic and any competitors' boilers of the same
class, you will find that Thermic is superior in all respects.
Especially in terms of energy costs. You will be satisfied
with its features backed by a reasonable price. Thermic
boilers are of high and uniform quality backed by
Thermic's overall technological power.
Compact Size
Thermic boilers are compact in design requiring less
installation space. Since no special boiler room is needed, it
can be mounted even in the corner of a workshop.
Easy To Operate
All the switches used for daily operation are mounted on
the front side making it easier to operate and handle.
Steam Is Generated in 10-15 Minutes
Thermic boilers generate steam at the prescribed pressure
in minutes after starting the operation. Quick steam
generation allows users to set work at any time.
 |
|
Steam Boiler TS20 |
|
|
 |
|
Steam Boiler TS5 |
|
BENEFITS
- Highest Efficiency - for lower running costs:
Independent tests of operating efficiency as high as 83%.
This is a full 3% higher than most others on the market.
- Fast Heat Up - start work faster:
Thermic boilers make steam faster than most other
boilers in their class.
- Compact Design - Smallest Floor Space:
Due to the vertical firing the THERMIC range has the
smallest "Foot-Print" in its class.
- Ease of Operation - minimal training and
maintenance:
All Thermic boilers are fully automatic and require
minimal maintenance.
- No Operator Certificates - anyone can operate:
All models comply to AS2593, this means no operator
certificates.*
A.S.M.E. models available.
- 24 Hours Per Day Service - faster response:
Thermic Boilers pride themselves on quality service
throughout Australia and many other countries using
qualified, efficient and cautious service personnel.
* Check with local authorities in countries other than
Australia
 |
|
High Pressure Steam Boiler
TSH30 |
|
|
 |
|
Steam Boiler
TS30 |
|
|
|
|
|
|
Thermic Model |
TS5 |
TS10 |
TS15 |
TS20 |
TS25 |
| Capacity (kW/Hp) |
50/5 |
100/10 |
150/15 |
200/20 |
250/25 |
| Evaporation Kg/Hr f & a
1000C |
80 |
160 |
240 |
300 |
375 |
| Heating Surface M2 |
2.23 |
4.4 |
6.75 |
8.95 |
11 |
| Fuel Usage Natural Gas M3/Hour |
5.6 |
11.4 |
16.8 |
22.8 |
28.1 |
| L.P.G. Lt/Hr |
8.6 |
16.54 |
26 |
33.88 |
43.4 |
| Diesel Oil Lt/Hr |
5.6 |
11.4 |
16.8 |
22.8 |
28.1 |
| Overall Height (mm) A |
1700 |
2070 |
2140 |
2350 |
2400 |
| Overall Width (mm) C |
500 |
600 |
700 |
820 |
980 |
| Overall Length (mm) B |
1000 |
1200 |
1300 |
1400 |
1500 |
| Flue Dia. (mm) ø |
125 |
150 |
150 |
200 |
200 |
| Feed water Inlet (mm) |
15 |
15 |
20 |
20 |
20 |
| Main Steam Outlet (mm) |
20 |
20 |
20 |
20 |
20 |
| Blow down Outlet (mm) |
15 |
20 |
20 |
20 |
20 |
| Safety Valve Outlet (mm) |
20 |
20 |
20 |
20 |
20 |
|